The mandatory access to Leonardo is the two-factor authentication (2FA). Please refer to this link of the User Guide to activate and connect via 2FA. For information about data transfer from other computers please follow the instructions and caveats on the dedicated section Data storage or the document  Data Management.

Accounting

In The accounting is still unavailable in this pre-production phase the accounting and will soon be soon availablefunctional.

For accounting information please consult our dedicated section.

...


Total Dimension (TB)

Quota (GB)

Notes

$HOME0.46 PiB70GB per user
  • permanent/backed up, user specific, local
$CINECA_SCRATCH41.4 PiBno quota
  • /leonardo_scratch/fast     (confinata sugli OST flash))
  • large (confinata sugli OST HDD)
  • temporary, user specific, local
  • no backup
  • automatic cleaning procedure of data older than 40 days (time interval can be reduced in case of critical usage ratio of the area. In this case, users will be notified via HPC-News)
$WORKnot yet available (10PB)
  • permanent, project specific, local
  • no backup
  • extensions can be considered if needed (mailto: superc@cineca.it)
  • work filesystem: the $WORK areas are not available yet. Until they will be configured and put in place the automatic cleaning of the scratch area will NOT be active.


It is also available a temporary storage local on compute nodes generated when the job starts and accessible via environment variable $TMPDIR. For more details please see the dedicated section of UG2.5: Data storage and FileSystems. On LEONARDO the $TMPDIR local area has 1 TB of available space.

...