Table of Contents |
---|
host login IP: 131.175.43.130
...
hostname: login.leonardo.cineca.it
early availability:
...
...
March, 2023
start of pre-production: May, 2023 (Booster)
last quarter 2023 (Data Centric
...
)
...
This system is the new pre-exascale Tier-0 EuroHPC supercomputer hosted by CINECA and currently built in the Bologna Technopole, Italy. It is supplied by ATOS, based on a BullSequana XH2135 supercomputer nodes, each with four NVIDIA Tensor Core GPUs and a single Intel CPU. It also uses NVIDIA Mellanox HDR 200Gb/s InfiniBand connectivity, with smart in-network computing acceleration engines that enable extremely low latency and high data throughput to provide the highest AI and HPC application performance and scalability.
...
Architecture: Atos BullSequana XH21355 "Da Vinci" blade - Booster (in β preproduction) Booster - Atos BullSequana X2610 compute blade - Data-centric (will be available in the last quarter of the 2023)
Internal Network: Nvidia Mellanox HDRDragonFly+ 200 Gb/s
Storage: 106 PB (raw) Large capacity storage, 620 GB/s
High Performance Storage 5.4 PB, 1.4 TB/s Based on 31 x DDN Exascaler ES400NVX2
...
|
---|
The
...
Leonardo is currently under testing by the vendor team, CINECA staff, and authorized external users. The environment is not finalized yet on storage, system configuration, and software stack.
...
following guide is already with the production configuration. In the very next days will begin the pre-production phase in which is mandatory the access via 2FA. Please refer to this link of the User Guide to activate and connect via 2FA
Peak performance details
Node Performance | ||
Theoretical | CPU (nominal/peak freq.) | 1680 Gflops |
GPU | 75000 Gflops | |
Total | 76680 GFlops | |
Memory Bandwidth (nominal/peak freq.) | 24.4 GB/s |
Access
All the login nodes have an identical environment and can be reached with SSH (Secure Shell) protocol using the "collective" hostname:
> login.leonardo.cineca.it
The mandatory access to Leonardo is the two-factor authentication (2FA). Please refer to this link of the User Guide to activate and connect via 2FA. For information about data transfer from other computers please follow the instructions and caveats on the dedicated section Data storage or the document Data Management.
Software environment
The available software environment is based on spack and modules, and needs to be activated. Some vendor installations are also available and presented in an lmod environment on the login node, but we warmly encourage the beta testers to use the spack environment to provide a valuable feedback on the software stack provided by CINECA.
...